R600a Refrigerant w/ Proseal Mini Inject with or without Dye

R290 & R600a


Please select an option from the list below:

Price/Option: Quantity:

Envirosafe R600a Refrigerant w/ Proseal Mini Inject with or without Dye Photo - Click to Enlarge

  • Kit includes:
    • ​1 can Enviro-Safe R600a Refrigerant 6 oz can
    • 1 each Proseal Mini Direct Inject or get it with Dye - you choose.
  • Our newest kit is perfect for those little R600a systems! 
  • Pharmaceutical grade 99.7% purity!
  • Perfect kit for a small job!
  • EPA approved R600a refrigerant for use as per EPA regulations 40 CFR Part 82.17
  • Designed for use in refrigeration units calling for R600 refrigerant
  • May be used in domestic refrigerators, freezers, dehumidifiers and window ac units
  • Also used in industrial applications: ice machines, grocery stores freezers, refrigerators, restaurant equipment, wine coolers, beer kegs, soda machines, drinking fountains, etc.
  • Sold in 6 oz cans
  • Proud to be a family owned business with over 22 years of experience! The oldest hydrocarbon refrigerant manufacturer in North America.
  • This product is flammable and you must use caution when installing this product.
  • This product is flammable to open flame or spark and is not intended for use in systems designed for non-flammable refrigerants.

DIRECTIONS FOR USE:

You must check & repair all leaks before charging. Read and understand all warnings and directions before
use. As per use with any flammable substance, take adequate precautions during use.
1. Install can tap valve and charging hose.
2. Install charging hose on low pressure side ONLY.
3. Invert can.
4. Fill system to correct pressure with the correct amount of refrigerant.
5. DO NOT overcharge the system.
6. Contact a licensed professional waste disposal service to dispose of this material.

 

Professional Use Only

Instructions for use:

Step 1: Turn the a/c system on, and verify the unit is running. Connect ProSeal Mini Inject to the low side service port of the system. (This is generally the large line.) 

Step 2: Connect the manifold refrigerant hose to the refrigerant supply tank. Verify the manifold high & low side valves on the manifold are closed before proceeding. Purge the air from the low side.

Step 3: Open low side valve, watch for the tube to clear. (This will ONLY take a few seconds!) Turn off low side manifold valve as soon as the tube is clear. Turn off refrigerant gas. Verify the system is charged to manufacturer’s specifications. Disconnect low side hose from ProSeal Mini Inject. Install service port cap. Run the a/c unit at least one hour after installing ProSeal Mini Inject.

Note: Do Not use Enviro-Safe ProSeal Mini Inject in any manner it was not designed! 