Auto/Home A/C Sealant Kit for R22/R134 Systems Ships Internationally #8125

Stop Leak & Sealants

$131.95 Quantity:

Envirosafe Auto/Home A/C Sealant Kit for R22/R134 Systems Ships Internationally #8125 Photo - Click to Enlarge

SDS

 Enviro-Safe Stop Leak VS (207 KB, PDF)
 Enviro-Safe ProDry VS (237 KB, PDF)
 Enviro-Safe ProSeal VS (293 KB, PDF)

International customers:  A kit that you've been waiting for!  This can ship domestically or internationally.  International has a flat fee for shipping no matter what the destination!

Designed to repair minor leaks in the evaporator, condenser, connecting fittings and metal lines. ProSeal was designed to save the consumer the burden of costly repairs in the form of replacement parts and expensive service labor. ProSeal can be used in all air-conditioning systems. (R12, R134a, R22 or R502) (also works in 410a systems, but you MUST CALL for instructions)

To be used in conjunction with Enviro-Safe ProDry.
 

ProSeal VS is a vacuum sealed can that is made for single use and may be used in most a/c systems such as R12, R134a.

ProDry Vacuum Seal (4 cans included in kit)
Enviro-Safe ProDry contains a dehydrating agent that converts system moisture into oil. We recommend the use of ProDry before the use of Enviro-Safe ProSeal to ensure all moisture has been removed from the air conditioning system.

ProDry VS is a vacuum sealed can that is perfect for the single use and may be used in most a/c systems such as R12, R134a, R22, and R502. Also works in 410a systems (must call for installation info)

Stop Leak Vacuum Seal (2 cans included in kit)

*For O Rings & Seals Only

Finally, a way to minimize the costly repairs to your auto air conditioner. Each and every year it is common to replace the lost refrigerant that leaks out over the winter months. This procedure is very costly and annoying and adds to the negligible affects to our environment with global warming.

Many leaks in the automotive air conditioner occur within the o-rings and seal areas. As o-rings and seals age, the materials begin to crack and shrink. Deterioration is the natural tendency of rubber and the heat from the engine exacerbates the deterioration.

Stop Leak VS is a vacuum sealed can that is perfect for the single use and may be used in most a/c systems such as R12, R134a.

Stop Leak VS

Read and understand all warnings and directions before use. This product must be used with a tap and hose that does not contain a back flo valve. The longer the system is charged with this product will give better results. Not for use with ammonia.
1. Install can tap valve and charging hose. 

2. Install charging hose on low pressure side ONLY 
3. Puncture can and back valve out to allow refrigerant to completely fill the can. 
4. Invert can and shake can well. 
5. Start A/C system. 
6. Install all product from can. 
7. Fill system to manufacturer’s specification pressure. 
8. Run compressor for a minimum of 30 min. to circulate product. 
9.  Turn can tap valve all the way down. 
10. Disconnect from low pressure valve. 
11. Disconnect can tap from tap and valve. 
12. Replace cap on low pressure valve. 
13. Discard empty can according to all rules and regulations for disposal in your area.

Proseal VS

Read and understand all warnings and directions before use.
1. Fill system to correct pressure with the correct amount of refrigerant as specified by the A/C manufacturer.
2. Shut off A/C system. 
3. Attach the can tap valve and charging hose to the can. 
4. Attach charging hose without a back-flow device on the low pressure side ONLY. 
5. Puncture the can, then open the valve to fill the can. 
6. Shake can well. 
7. Start the A/C system. 
8. Invert the can. 
9. Open the valve. 
10. When the can is empty, shut off the valve. 
11. Shut system off. 
12. Disconnect from low pressure valve. 
13. Disconnect can from tap and valve. 
14. Turn A/C thermostat down and open doors or windows to allow the A/C compressor to run for a minimum of 30 minutes. 
15. Discard empty can in accordance with all local, regional, national, and international regulations.  
 
ProDry VS
 
Check system pressure and make sure system is charged properly before installing product. Make sure system is off before connecting to the system.
1. Make sure piercing device it threaded up all of the way before screwing the can on. Install can tap valve and charging hose. 
2. Install charging hose on low pressure valve. 
3. Puncture can and back valve out to allow refrigerant to completely fill the can. 
4. Invert can and shake well. 
5. Start A/C system. 
6. Install all of product from can. 
7. Fill system pressure to manufacturer specification. 
8. Run compressor for a minimum of 30 minutes to circulate product. 
9. Turn can tap valve all the way down. 
10. Disconnect from low pressure valve. 
11. Disconnect can from tap and hose. 
12. Replace cap on low pressure valve. 
13. Dispose of contents/container according to local, regional, national, and international regulations.
Note: This product must be used with a tap and hose that does not contain a back-flow valve. The longer the system is operated after it is charged with the product will lead to better results. The A/C system must operate before inserting this product. Not for use with ammonia.

Newsletter Signup: